XSelect HSS CN 柱是—款超高性能通用的丙基氰基键合相,提供优越的峰形,增加保留,在低PH值条件下具有延长柱寿命。高强度硅胶颗粒(HSS)技术专为补充杂化BEH和CSH颗粒开发,用于提高色谱效率。高孔径容量的硅胶基质HPLC颗粒不具备必要的机械稳定性来承受UPLC分离过程中的压力,如果实验室需要将现有的HPLC方法转移到UPLC系统上的话,这一点就显得尤为重要。机械稳定性的限制促使沃特世的科学家设计出一种颗粒具有高机械稳定性和较长的使用寿命以及高压下的UPLC的柱效。
XSelectHSS CN色谱柱可被成功用于正相和反相分离,是多样化的固定相。
Determination of Soy Isoflavones in Foods and Dietary Supplements by UPLC
Isoflavones are a class of plant-derived compounds, produced almost exclusively by members of the Fabaceae family, that have been shown to have estrogenic activity in mammals. The major source of isoflavones in the human diet comes from soybeans, in which genistein and daidzein are the predominant components. Isoflavones remain the subject of many scientific studies with accepted methods established by organizations such as AOAC1 and USP2 , utilizing traditional reversed-phase C18 columns. Recently, the National Institute of Standards and Technology (NIST) has developed a suite of soy-based candidate Standard Reference Materials (cSRMs) for the certification of soy isoflavones in foods and dietary supplements. For the analysis of those standards, they have developed a method utilizing a 60-minute gradient on a 5 µm cyano column which enables the separation of the soy isoflavones from other components not resolved using the standard C18 methods.3 Using these conditions, they have demonstrated resolution of the three main soy isoflavones and their glycosides (structures shown in Figure 1), as well as the acetyl and malonyl conjugates of the glycosides. Since the conjugates are somewhat unstable in solution, they have added an additional sample preparation step to hydrolyze these conjugates to their associated glycoside, providing a more accurate, reproducible determination of total isoflavone content. Optimization of this method utilizing the XSelect HSS Cyano XP 2.5 µm Column provides a significant reduction in analysis time by traditional HPLC. Further optimization of this method to UPLC® with the ACQUITY UPLC HSS Cyano 1.8 µm Column provides additional savings in time, while maintaining the resolution for accurate determination of soy isoflavones.
品名 | 编号 |
XSelect HSS Cyano (CN) Column, 100Å, 3.5 µm, 1 mm X 100 mm, 1/pkg | 186005903 |
XSelect HSS Cyano (CN) Column, 100Å, 3.5 µm, 1 mm X 150 mm, 1/pkg | 186005904 |
XSelect HSS Cyano (CN) Column, 100Å, 3.5 µm, 2.1 mm X 30 mm, 1/pkg | 186005906 |
XSelect HSS Cyano (CN) Column, 100Å, 3.5 µm, 2.1 mm X 50 mm, 1/pkg | 186005907 |
XSelect HSS Cyano (CN) Column, 100Å, 3.5 µm, 2.1 mm X 75 mm, 1/pkg | 186005908 |
XSelect HSS Cyano (CN) Column, 100Å, 3.5 µm, 2.1 mm X 100 mm, 1/pkg | 186005909 |
XSelect HSS Cyano (CN) Column, 100Å, 3.5 µm, 2.1 mm X 150 mm, 1/pkg | 186005910 |
XSelect HSS Cyano (CN) Column, 100Å, 3.5 µm, 3 mm X 100 mm, 1/pkg | 186005915 |
XSelect HSS Cyano (CN) Column, 100Å, 3.5 µm, 3 mm X 30 mm, 1/pkg | 186005912 |
XSelect HSS Cyano (CN) Column, 100Å, 3.5 µm, 3 mm X 50 mm, 1/pkg | 186005913 |
XSelect HSS Cyano (CN) Column, 100Å, 3.5 µm, 3 mm X 150 mm, 1/pkg | 186005916 |