Xselect HSS PFP Column
氟苯基柱;反相模式
应用领域

五氟苯基(PFP:Pentafluorophenyl,或又称全氟苯基)配体提供多重保留机制包括:氢键作用、偶极-偶极作用、芳香性(π-π)作用,以及疏水(反相)作用,当试图分离异构性的、芳香性的、或是卤代的化合物特别有用。

含氟固定相为常规C18提供了互补的色谱分离选择性,特别是当需要分析碱性或平面芳香族化合物时。XSelectHSS PFP和CSH氟苯基色谱柱具有相同配体,但是不同的颗粒基体提供了不同的保留特性


XSelectTM HSS(高强度硅胶颗粒)系列HPLC色谱柱一直在不断地  扩展其选择范围,现在新增一种五氟苯基[PFP]键合相。该新  款XSelect HSS PFP色谱柱是目前稳定性好且具重现性且可扩展的以硅胶颗粒为基质的PFP LC色谱柱。其HSS基质及PFP  配体为您提供真正的PFP性能,同时不牺牲峰形,也不会有保留时间不重现的问题。

Development of LC-MS/MS method for determination of plasma iopamidol


Objective To develop a stable LC-MS/MS method for the determination of iopamidol in human plasma and evaluate the performance of the method. Methods Deuterium isotope was used as internal standard. Plasma samples were pretreated by direct precipitation,separated by XSelectTMHSS PFP column and equally eluted by 10% acetonitrile solution containing 0.1% fomic acid and 5 mmol/L nonafluoropentanoic acid. The detection was performed by ionic scanning with positive-ion electrospray and the results were analyzed by multiple reaction monitoring( MRM) mode. According to the CLSI EP10-A and CLSI C62-A standards,the linear range,accuracy,precision,specificity,matrix effect and stability of the method were evaluated. Results The linear range of iopamidol determined by LC-MS/MS was 1 to 1 000 μg I/mL( calculated with iodine content). The deviations between the determined results and the theoretical target values were from -6.1% to 7.5% in low,medium and high concentrations of plasma samples( 3,50 and 800 μg I/m L).The repeatability was expressed as imprecision with CV less than 6.6%( 4.6% to 6.6%). The intermediate precision was expressed with CV less than 8.5%( 6.6% to 8.5%). The recoveries were from 92.5% to 95.9%. The matrix effects of the method were from 88.8% to 95.2%. The results of the method showed excellent selectivity,since hemolysis and lipemia did not affect the results. In terms of this method,plasma samples had better kept at room temperature for no more than 48 hours and repeatedly freeze-thaw from -80 ℃ for no more than 2 times,so that iopamidol could almost still be stably detected. Iopamidol was also stable in extracted samples at 4℃ in the autosampler for 72 hours. Conclusion A reliable LC-MS/MS method for determination of iopamidol in human plasma was established and evaluated.

品名

规格

编码

XSelect HSS PFP Column

100Å, 3.5 µm, 1 mm X 150 mm,  1/pkg

186005844

XSelect HSS PFP Column

100Å, 3.5 µm, 2.1 mm X 100 mm,  1/pkg

186005849

XSelect HSS PFP Column

100Å, 5 µm, 2.1 mm X 150 mm,  1/pkg

186005872

XSelect HSS PFP Column

100Å, 5 µm, 2.1 mm X 100 mm,  1/pkg

186005871

XSelect HSS PFP Column

100Å, 3.5 µm, 3 mm X 30 mm,  1/pkg

186005852

XSelect HSS PFP Column

100Å, 3.5 µm, 3 mm X 50 mm,  1/pkg

186005853

XSelect HSS PFP Column

100Å, 3.5 µm, 3 mm X 75 mm,  1/pkg

186005854

XSelect HSS PFP Column

100Å, 3.5 µm, 3 mm X 100  mm,

186005855

XSelect HSS PFP Column

100Å, 3.5 µm, 3 mm X 150 mm,  1/pkg

186005856

XSelect HSS PFP Column

100Å, 5 µm, 3 mm X 50 mm,  1/pkg

186005875

XSelect HSS PFP Column

100Å, 3.5 µm, 4.6 mm X 30 mm,  1/pkg

186005858

XSelect HSS PFP Column

100Å, 3.5 µm, 4.6 mm X 50 mm,  1/pkg

186005859

XSelect HSS PFP Column

100Å, 5 µm, 3 mm X 100 mm,  1/pkg

186005877

XSelect HSS PFP Column

100Å, 5 µm, 3 mm X 150 mm,  1/pkg

186005878

XSelect HSS PFP Column

100Å, 3.5 µm, 4.6 mm X 250 mm,  1/pkg

186005863

XSelect HSS PFP Column

100Å, 3.5 µm, 4.6 mm X 150 mm,  1/pkg

186005862

XSelect HSS PFP Column

100Å, 3.5 µm, 4.6 mm X 100 mm,  1/pkg

186005861

XSelect HSS PFP Column

100Å, 3.5 µm, 4.6 mm X 75 mm,  1/pkg

186005860

XSelect HSS PFP Column

100Å, 5 µm, 4.6 mm X 30 mm,  1/pkg

186005881

XSelect HSS PFP Column

100Å, 5 µm, 4.6 mm X 100 mm,  1/pkg

186005884

XSelect HSS PFP Column

100Å, 5 µm, 4.6 mm X 150 mm,  1/pkg

186005885

XSelect HSS PFP Column

100Å, 5 µm, 4.6 mm X 250 mm,  1/pkg

186005886

XSelect HSS PFP Column

100Å, 5 µm, 2.1 mm X 30 mm,  1/pkg

186005868

XSelect HSS PFP Column

100Å, 5 µm, 2.1 mm X 50 mm,  1/pkg

186005869

XSelect HSS PFP Column

100Å, 3.5 µm, 2.1 mm X 75 mm,  1/pkg

186005848

XSelect HSS PFP Column

100Å, 3.5 µm, 2.1 mm X 30 mm,  1/pkg

186005846

XSelect HSS PFP Column

100Å, 3.5 µm, 2.1 mm X 50 mm,  1/pkg

186005847

XSelect HSS  PFP Method Validation Kit

100Å, 2.5 µm, 2.1 mm X  50 mm, 3/pkg

186006815

XSelect HSS  PFP Method Validation Kit

100Å, 2.5 µm, 3 mm X 50 mm,  3/pkg

186006817

XSelect HSS  PFP Method Validation Kit

100Å, 2.5 µm, 2.1 mm X 100 mm,  3/pkg

186006816

XSelect HSS  PFP Method Validation Kit

100Å, 2.5 µm, 4.6 mm X 100 mm,  3/pkg

186006274

XSelect HSS  PFP Method Validation Kit

100Å, 2.5 µm, 4.6 mm X 50 mm,  3/pkg

186006273

XSelect HSS  PFP Method Validation Kit

100Å, 2.5 µm, 3 mm X 100 mm,  3/pkg

186006818

XSelect HSS  PFP Method Validation Kit

100Å, 2.5 µm, 2.1 mm X 150 mm,  3/pkg

186006803

XSelect HSS  PFP Method Validation Kit

100Å, 2.5 µm, 3 mm X 150 mm,  3/pkg

186006804

XSelect HSS  PFP Method Validation Kit

100Å, 2.5 µm, 4.6 mm X 150 mm,  3/pkg

186006805


相关产品

联系我们
把您的需求告诉我们,让我们优秀的团队为您服务!
即问即答,我们在线为您服务!


请关注 :暄泓仪器-官方微信
咨询热线
021-61650697
Copyright 2018 相关版权归上海暄泓科学仪器有限公司所有 网站备案/许可证号:沪ICP备18035879号-1